Product model | KCJXF (single phase) | KCJXF (three-phase) |
Installed power | 3KW-20KW | 3KW-200KW |
The number of inverter input channels | 1 way/2way/3way/4way(It is recommended to use a combiner box as above) |
Grid-connected output channels | 1 way |
Grid connection requirements | Single-phase/three-phase grid connection |
Grid-connected voltage | AC:220 AC:380 |
Switching capacity | 20A-100A | 32A-400A |
Protective function: | Have |
Short circuit protection | Have |
Overload protection | Have(Nominal current: In: 20KA, Imax: 40KA, Up≤4KV) |
Isolation Protection (Visual Breakpoints) | Have(knife switch/hand-pull disconnector) |
Overvoltage and undervoltage protection | Have |
Automatic reclosing | Have |
Grid-connected switch: | | |
Self-resetting overvoltage and undervoltage protector (optional) 40A~125A | 1. When the power grid is powered off or the bias voltage is greater than 20%, it will automatically disconnect (internal disconnection); 2. When the power grid returns to normal, it will automatically pull in (internally connected) |
Photovoltaic special small reclosing circuit breaker (optional) 20A~100A | 1. When the power grid is powered off or the bias voltage is greater than 20%, it will automatically open (operating handle action); 2. When the power grid returns to normal, it will automatically close (operating handle action) 3. Manual operation and automatic operation can be switched 4. Check the voltage closing |
Plastic case recloser (optional) 40A~400A | 1. When the power grid is powered off or the bias voltage is greater than 20%, it will automatically trip (the delayed tripping time is adjustable from 0-10S); 2. When the power grid returns to normal, it will automatically close 3. Manual operation and automatic operation can be switched 4. Check the voltage closing 5. Phase loss protection, zero-break protection |
Applicable environment: | | |
Temperature, humidity | Working temperature: -25 to +60 °C Storage temperature: -40 to +70 °C, humidity: 0-90% no condensation; no corrosive gas place (if any, please specify) |
Use altitude | ≤3000M |
Salt spray resistant | Standard salt spray test 336 hours |
General parameters: | | |
Box material | Stainless steel, cold-rolled plate spray, stainless steel spray, glass fiber reinforced plastic (SMC), transparent plastic box |
Protection class | Outdoor IP45/IP55/IP65 |
Box type | Double door with meter (power distribution bin, metering bin) single door without measuring bin (optional) |
Installation method | Wall-mounted |
Box size (L*W*H) | Customized on demand |